{"product_id":"km204-multi-current-stimulator-precision-device-used-for-cra","title":"KM204 Multi-current Stimulator Precision Device Used for Cra","description":"\u003cdiv class=\"J_module\"\u003e\n\u003cdiv class=\"detail-decorate-json-renderer-container\"\u003e\n\u003cdiv class=\"magic-0\"\u003e\n\u003cdiv class=\"magic-1\"\u003e\n\u003cdiv class=\"magic-2\"\u003e\n\u003cdiv class=\"magic-3\"\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003cspan class=\"magic-7\"\u003eThe Multi-current stimulator is a precision device used for cranial electrotherapy stimulation for the treatment of anxiety and\u003cbr\u003einsomnia. When it is used in connection with nasal electrodes, it can be used to relieve symptoms of rhinitis and nasal\u003cbr\u003econgestion.\u003cbr\u003eFeatures\u003cbr\u003eSAFE OUTPUT INTENSITY.\u003cbr\u003eTHREE TYPES OF ELECTRODES DUAL CHANNELS WITH FLEXIBLE CONTROL SETTINGS.\u003cbr\u003ePALM-FITTING SIZE DEVICE.\u003cbr\u003eWIDE RANGE OF TREATMENT OPTIONS.\u003c\/span\u003e\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003cspan class=\"magic-7\"\u003eCOMBINATION OF MICROCURRENT AND TENS\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"magic-8\"\u003e\u003cspan class=\"magic-6\"\u003e\u003cspan class=\"magic-5\"\u003eDescription\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"magic-7\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e\u003cspan class=\"magic-7\"\u003e\u003cbr\u003eThe stimulator is small, compact and light-weight. It was designed to be versatile. It can be used in a healthcare practitioner's office, clinic or hospital, for portable and quick response needs such as emergency medical or military applications, as well as for self-administered treatment at home on a scheduled or as-needed basis.\u003cbr\u003e\u003cbr\u003eThe stimulator has three different output modes, corresponding to two independent output channels. Channel 1 uses an ear clip electrodes to act on the earlobes, and channel 2 uses an electrode pads behind the ears, which are adhered to the mastoid process behind the ears. The current is applied by ear clip electrodes and the electrode pads behind the ears for anxiety and insomnia. Channel 2 can also be connected to a nasal electrode to stimulate the nasal side.When you use the nasal electrode, electrical stimulation will be output on the nasal side to help improve blood circulation in the nasal area and accelerate the relief of\u003cbr\u003enasal symptoms. The amount of current can easily be increased to reduce treatment time or decreased when necessary to assure comfort.\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan class=\"magic-7\"\u003e\u003cbr\u003e\u003cspan\u003eHow To Use\u003c\/span\u003e\u003cbr\u003e1 Charge the battery\u003cbr\u003e2 Connect the electrodes to the unit\u003cbr\u003e3 Placing electrodes\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan class=\"magic-7\"\u003e\u003cbr\u003e\u003cspan\u003eFor Earlobe:\u003c\/span\u003e\u003cbr\u003eConnect the electrode wire to CH1 and then connect the two ear clip electrodes. Attach the ear clip electrodes to the two earlobes respectively. The two ear clips do not need to be distinguished.\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eFor Mastoid process:\u003c\/span\u003e\u003cbr\u003eConnect the electrode wire at CH 2 and then attach the electrode pads and peel off the plastic covering. Stick the electrode pad firmly behind the right ear ensuring you have removed any hair from the area. Ensure the pad is securely attached. Repeat with the\u003cbr\u003eleft side.\u003cbr\u003e\u003cspan\u003eTip: \u003c\/span\u003eTake your right index finger and middle finger and place the index finger just behind your right earlobe on the mastoid area (bony part). The placement of your middle finger is where you’ll place the pad. Repeat with left side.\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eFor Nasal Side:\u003c\/span\u003e\u003cbr\u003eInsert the plug of the nose electrode into the CH2 socket of the stimulator. Wear the nose electrode on your head, fix the electrode part on the side of your nose, and adjust the tightness of the headband to ensure it is secure.\u003cbr\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan class=\"magic-7\"\u003e4 Turn on the device\u003cbr\u003e5 Select the modes\u003cbr\u003e6 Set time and Adjust the intensity\u003cbr\u003e7 Turn off the device\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan class=\"magic-7\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan class=\"magic-7\"\u003e\u003cspan\u003eCheck List\u003cbr\u003e* 1 stimulator\u003cbr\u003e* 2 ear clip electrodes\u003cbr\u003e* 2 electrode pads behind the ears\u003cbr\u003e* 1 Nasal electrode\u003cbr\u003e* 2 Electrode wires (white)\u003cbr\u003e* 1 bottle of conductive liquid\u003cbr\u003e* 1 Charging wire（Type-C plug）\u003cbr\u003e* 1 User Manual\u003c\/span\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"J_module\"\u003e\n\u003cdiv id=\"ali-anchor-AliMagic-2coodr\" class=\"magic-9\"\u003eSpecification\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"J_module\"\u003e\n\u003cdiv class=\"ife-detail-decorate-table\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-11\"\u003ePower supply\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-12\"\u003eDC 3.7V\/ 900mAh rechargeable lithium battery\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-11\"\u003eCharging port voltage\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-12\"\u003eDC 5V, 0.5A\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-11\"\u003eSafety Category\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-12\"\u003eBF type\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-11\"\u003eNumber of channels\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-12\"\u003e2\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-11\"\u003eDisplay\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-12\"\u003eFull-color, 2.8\" TFT screen\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-11\"\u003eOutput Waveform\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-12\"\u003eSquare, Rectangular, monophasic\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-11\"\u003eFrequency\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-12\"\u003eCARE: 0.67 Hz (fixed), PAIN: 200 Hz (max.), MCR: 400 Hz (max.)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-11\"\u003eTimer\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-12\"\u003e10, 20, 30, 40 or 60 minute countdown timers.\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-11\"\u003eMaximum amplitude\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-12\"\u003eEarlobe Mode: 0-600μA;\u003cbr\u003eMastoid process Mode: 0-1500μA;\u003cbr\u003eNasal Side Mode: 0-30mA.\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-11\"\u003eMaximum output level\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-12\"\u003eEarlobe Mode: Level 10;\u003cbr\u003eMastoid process Mode: Level 20;\u003cbr\u003eNasal Side Mode: Level 40.\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-11\"\u003eFrequency\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-12\"\u003e0.5Hz, 100Hz.\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-11\"\u003ePulse width\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-12\"\u003e150μs, 2.5ms ,250ms, 500ms, 750ms, 1000ms\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-11\"\u003eDuty cycle\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-12\"\u003e50%\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-11\"\u003eDimensions\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-12\"\u003e135x64x15mm\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-11\"\u003eWeight\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-12\"\u003e70 g (including a battery)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-11\"\u003eService life\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-12\"\u003e5 years\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-11\"\u003eEnvironment for Operation\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-12\"\u003eTemperature:5℃~40℃; Humidity:≤80%RH; Atmospheric pressure: 70~106kPa\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-11\"\u003eEnvironment for Transportation \u0026amp; Storage\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-12\"\u003eTemperature: -10℃~+55℃; Humidity: ≤90%RH; Atmospheric pressure: 50~106kPa\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"J_module\"\u003e\n\u003cdiv id=\"ali-anchor-AliMagic-23fxyn\" class=\"magic-9\"\u003eProduct Description\u003c\/div\u003e\n\u003c\/div\u003e","brand":"JYTOP","offers":[{"title":"Default Title","offer_id":43835741306940,"sku":"KM204 ","price":115.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0026\/5004\/6524\/files\/11_1a40510d-0384-41af-9081-409ad9002f77.jpg?v=1768353950","url":"https:\/\/jytoponline.com\/de\/products\/km204-multi-current-stimulator-precision-device-used-for-cra","provider":"JYTOP","version":"1.0","type":"link"}