{"product_id":"ms400-multi-parameter-signal-patient-simulator-medical-ecg","title":"JYTOP MS400 Multi Parameter Signal Patient Simulator Medical Ecg","description":"\u003cp\u003e\u003cspan\u003eIntroduction:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eMS400 Multiparameter Simulator is a portable device, features in small volume and light weight. It can simulate accurately 12-lead ECG, Respiration, Temperature, 2-channel IBP or 4-channel IBP. And it can be tested in where the monitor is used.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0026\/5004\/6524\/files\/2-260112103049616_bd165d9a-641f-4102-ab80-96b447d6d71e.jpg?v=1768443888\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0026\/5004\/6524\/files\/2-260112103049535_8ff8fd88-bb5b-4651-b749-237ddd58ed3e.jpg?v=1768443888\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0026\/5004\/6524\/files\/Main-06_4ff04e2c-6dcd-423c-a7bd-92e0a9cb3349.jpg?v=1768443888\" alt=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFeatures:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eSimulate 35 kinds of arrhythmia (including Atrial, Ventricular, Premature Beat and Conduction Defects) and pacemaker waveforms (including Asynchronous, Demand Occ Sinus, Demand Freq Sinus, A\/V Sequential, Non Capture, Non Function).\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eSimulate four-channel IBP data.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eSimulate respiration signal with adjustable respiration rate, impedance and baseline impedance, and three kinds of apnea data.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eSimulate four kinds of temperature data.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eSimulate square wave, triangle wave, pulse wave and sine wave with adjustable frequency.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eSimulate standard ECG calibration, adult and pediatric ECG signal.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eECG waveform complied with the standard of ANSI\/AAMI EC13-2002, AHA, MIT ECG database, other ECG database and user-defined waveform data stored in TF card can be displayed by the simulator and exported to the equipments to be tested.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eEach waveform can be displayed by sliding the 3.5'' TFT touch screen, easy to operate.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ePower supply: rechargeable lithium battery or linear adapter, which reduces interference.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eOptional operation modes: keys and touch screen.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eParameters:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eECG\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eConventional: All leads have the same voltage with the II-lead as the reference\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eAmplitude: 0.5,1.0,1.5 and 2.0mV\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eECG Rate: 15,20,25,30,40,60,80,100,120,140,160,180,200,220,240,260,280,300,320,340 and 350 BPM\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eECG artifacts: 50 and 60 Hz, muscle, baseline and breathing\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThe elevation of the ST segment: +0.8 to -0.8 mV, the step is 0.1 mV\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eArrhythmia:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eAtrial: Atrial Fib(coarse), Atrial fib(fine), Atrial Flutter, Sinus Arrhythmia, Missed Beat, Atrial Tachycardia, Nodal Rhythm, Supraventricular Tachycardia\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eVentricular: Vent Fib (coarse), Vent Fib (fine), PVCs 6\/min, PVCs 12\/min, PVCs 24\/min, Frequent Multifocal, Bigeminy, Trigeminy, Paired PVCs, Run 5 PVCs, Run 11 PVCs, Vent Tachycardia, Asystole\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ePremature Beat: Atrial PAC, Nodal PNC, PVC1 LV Focus, PVC1 E LV Focus, R on T LV Focus, PVC2 RV Focus, PVC2 E RV Focus, R on T RV Focus, Multifocal PVC\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eConduction Defects: First Degree Heart Block, Second Degree Heart Block, Third Degree Heart Block, Right Bundle Branch Block, Left Bundle Branch Block\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFour IBP Channels:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThe default: 00\/00mmHg\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eDynamic IBP(unit: mmHg)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eChannel 1:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eArtery: 120\/80\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eRadial: 120\/80\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eLeft Ventricle: 120\/00\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eRight Ventricle: 25\/00\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eChannel 2:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eArtery: 120\/80\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eRadial: 120\/80\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eLeft Ventricle: 120\/00\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eRight Atrium(CVP): 15\/10\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eRight Ventricle: 25\/00\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ePulmonary Artery: 25\/10\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ePulmonary Wedge: 10\/2\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eLeft Atrium: 14\/4\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eChannel 3:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eArtery: 120\/80\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eRadial: 120\/80\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eLeft Ventricle: 120\/00\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eRight Atrium(CVP): 15\/10\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eRight Ventricle: 25\/00\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ePulmonary Artery: 25\/10\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ePulmonary Wedge: 10\/2\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eLeft Atrium: 14\/4\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eChannel 4:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eAuto Swan-Ganz (every 15 seconds): RA(CVP), RV, PA, PAW (Pulmonary Wedge)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eMan Swan-Ganz: press ENTER key to change every time\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eStatic-Pressure Levels\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eChannel 1: 0, 80, 160, 240, 320 and 400mmHg\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eChannel 2: 0, 50, 100, 150, 200 and 250mmHg\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eChannel 3: 0, 20, 40, 60, 80 and 100mmHg\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eChannel 4: P4 tracks the static pressure levels of P3\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eRespiration:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eRespiration Rate: 0 (Apnea), 15, 20, 30, 40, 60, 80, 100, 120 and 150 R\/MIN\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eImpedance: 0.2, 0.5, 1.0 and 3.0 Ω\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eBaseline impedance: 500, 1000, 1500, 2000Ω\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eApnea: 12 s, 22 s, 32 s\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTemperature:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eFour temperature: 0℃(32°F), 24℃( 75°F), 37℃(98.6°F), 40℃(104°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePhysical characteristic:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eDimension 18.86 cm(L)×12.50 cm(W)×4.32 cm(H)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eNet weight about 1.4kg\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePackage included:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1XMS400 Multiparameter Simulator\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1X Temperature cable\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1XIBP cable\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1XPower adapter\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1XUser manual\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1XPackaging box\u003c\/span\u003e\u003c\/p\u003e","brand":"JYTOP","offers":[{"title":"EU Plug","offer_id":43947509547068,"sku":"MS400","price":499.0,"currency_code":"USD","in_stock":true},{"title":"US Plug","offer_id":43947509579836,"sku":"MS401","price":499.0,"currency_code":"USD","in_stock":true},{"title":"UK Plug","offer_id":43947509612604,"sku":"MS402","price":499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0026\/5004\/6524\/files\/Main-02_7dbc0c9f-5762-4892-9c6a-6a7d53b152dc.jpg?v=1768443843","url":"https:\/\/jytoponline.com\/ru\/products\/ms400-multi-parameter-signal-patient-simulator-medical-ecg","provider":"JYTOP","version":"1.0","type":"link"}