Instructions

Principle of the CMS60F Pulse Oximeter is as follows: Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning & Recording Technology,the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger.The product is suitable for being used in family, hospital, oxygen bar, community healthcare, physical care in sports (It can be used before or after doing sports, and it is not recommended to use the device during the process of having sport) and etc. 

Major Features

◆ Small in volume、light in weight and convenient in carrying

◆ Operation of the product is simple ,low power consumption

◆ Operation menu for the function setting

◆ SpO2 value display

◆ Pulse rate value display, bar graph display

◆ Pulse waveform display

◆ PI Display

◆ Screen brightness can be changed

◆ A pulse rate sound indication

◆ With measured data overruns limits and low-voltage alarm function,the upper/down alarm range can be adjustable

◆ Battery capacity indication

◆ Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage ,and with alarm function

◆ With clock function

◆ Review function

◆ With data record function of multiuser, continuous record  about 24 hours data for each user, and the record data can be uploaded to computer

◆ Touch key operation and locking touch key function

◆ It can be connected with adult,child,infant oximeter probe

◆ Wireless communication function(CMS60FW)

Main performance

◆ Display Mode:2.8" TFT Color display

◆ Screen Resolution:320*240

◆ SpO2 Measuring Range:0%~100%, (the resolution is 1%).

◆ Accuracy:70%~100%:±2% ,Below 70% unspecified.

◆ PR Measuring Range:30bpm~250bpm, (the resolution is 1bpm)

◆ Accuracy:±2bpm or ±2% (select larger)

◆ Measurement Performance in Weak Filling Condition:SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).

◆ Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.

◆ Voltage:DC 3.6V~4.2V

◆ Power Supply:Voltage 3.7 rechargeable lithium battery × 1  

◆ Battery working hour: 8 hours

◆ Battery working life:Charge and discharge no less than 500 times.

◆ Safety Type:Interior Battery,BF Type

Accessories

Sell in standard

◆ a user manual(GB only)on request for other Language

◆ A power adapter(GTM41076-0605;CMS0105)

◆ a data line

◆ An oximeter probe

Sell in addition

Other Oximeter Probe (Refer to probe application instruction for details and notice renewal)

Physical Identity

Dimension:94.25(L) × 55.32(W) × 9.6(H) mm

Weight:About 80g (with a lithium battery)