JYTOP MS200 NIBP Simulator Blood Pressure Monitor Accuracy Simulation Test

Prezzo scontato $789.00 Prezzo di listino $1,420.00

Spese di spedizione calcolate al momento del pagamento.

Product overview
MS200 NIBP Simulator is a multi-purpose test instrument for use with oscillometric Non-Invasive Blood Pressure(NIBP) Monitors. The appearance is concision ,operation is simple and convenient,with its internal pump, the Simulator can generate pressures up to 400 mmHg (53.3 kPa).The Simulator provides dynamic blood pressure simulations, static pressure calibration, automated leak testing, and pressure relief valve testing.You can quickly and exact analyse different NIBP Monitors.

Main features

  1. Provides pressure gauge testing,pressure leak testing,relief valve testing functions .
  2. Build-in pump provides pressure source with leak and pressure relief tests
  3. NIBP simulations for both arm and wrist cuffs.
  4. Provides adult,neonate, eight variations patients conditions,user-defined simulations.
  5. Provides arrhythmias,respiratory artifact simulations.
  6. Built-in air chamber to simulate adult and neonate cuff.
  7. 65k colors,4.3" LCD display.

Technical index

 

  • Pressure measurement
    Units:mmHg,kPa,cmH2O,inH2O,psi
    Range:0mmHg-400mmHg
    Resolution:1 mmHg,0.1 kPa,1 cmH2O,1 inH2O,0.1 psi
    Accuracy:0-300 mmHg:±0.5% of reading ±1 mmHg;
        301-400 mmHg:±2%of reading
  • Pressure Generator
    Static Pressure Range:50 mmHg-400 mmHg
    Resolution:1mmHg
    Difference between target pressure and actual pressure :±10 mmHg from 100-400 mmHg with a minimum volume of 300 cc
  • Internal leak rate
    <2 mmHg per minute, with a minimum volume of 300 cc
  • Pressure Leak Test
    Pressure generate up to 400 mmHg (53.3 kPa) with internal pump.The screen always show the peak pressures and the real-time pressures.Leak rate displayed after 10 seconds.
  • Pressure Relief Test
    Pressure generate up to 400 mmHg (53.3 kPa) with internal pump,Displays peak pressure.
  • Standard BP Simulations
    Preset blood pressure:
      1#: BP: 120/80(93) HR: 80 Pulse Volume: 0.68
      2#: BP: 150/100(116) HR: 80 Pulse Volume: 0.65
      3#: BP: 200/150(166) HR: 80 Pulse Volume: 0.60
      4#: BP: 255/195(215) HR: 80 Pulse Volume: 0.55
      5#: BP: 60/30(40) HR: 80 Pulse Volume: 0.75
      6#: BP: 80/50(60) HR: 80 Pulse Volume: 0.71
      7#: BP: 100/65(76) HR: 80 Pulse Volume: 0.69
  • Patient Conditions
    BP Simulations
      Healthy: BP: 120/80(93) HR:75 Pulse Volume: 0.68
      Weak Pulse: BP: 110/80(90) HR:95 Pulse Volume: 0.50
      Mild Exercise: BP: 140/90(106) HR:120 Pulse Volume: 1.00
      Strenuous Exer: BP: 140/90(106) HR:162 Pulse Volume: 1.40
      Obese: BP: 120/80(93) HR:90 Pulse Volume: 0.50
      Geriatric: BP: 150/110(123) HR:95 Pulse Volume: 0.40
      Tachycardia: BP: 120/105(110) HR:130 Pulse Volume: 0.40
      Bradycardia: BP: 120/60(80) HR:45 Pulse Volume: 1.10
  • Arrhythmia Simulations
    Premature Atrial Contract 1,Premature Atrial Contract 2,Premature Ventricular Contract,Atrial Fib and PVCs
  • Respiratory Artifacts
    Spontaneous Breathing 1,Spontaneous Breathing 2,Spontaneous Breathing 3,Controlled Ventilation
  • Neonate simulations
    User can select External or Internal Neonate;
      1#: BP: 35/15 HR: 120bpm Pulse Volume: 0.11
      2#: BP: 60/30 HR: 120bpm Pulse Volume: 0.10
      3#: BP: 80/50 HR: 120bpm Pulse Volume: 0.10
      4#: BP: 100/70 HR: 120bpm Pulse Volume: 0.10
  • Wrist simulations
    1#: BP:120/80(93) HR: 80bpm Pulse Volume: 0.50
    2#: BP:160/100(120) HR: 80bpm Pulse Volume: 0.50
    3#: BP:80/55(63) HR: 80bpm Pulse Volume: 0.50
  • User-Defined simulations
    Allows the operator to define blood pressure simulations.
      Systolic(mmHg) 20-250
      Diastolic(mmHg) 10-200
      Heart Rate,(bpm) 30-250
      Pulse Volume,(cc) 0.1-2.4
  • Simulant characteristics
    The maximum pulse volume:2.4cc
    The maximum heart rate:250bpm,200bpm at pulse volume>2.00cc.
    Internal Adult cuff volume:20cc
    Internal neonate cuff volume:300cc
    Blood pressure units: mmHg,kPa
    Heart Rate Accuracy:±1BPM
    Patient Conditions:
      Weak pulse, Tachycardia,Obese,Geriatric ±1%±1BPM
      Mild exercise±1.5%±1BPM
      Strenuous exercise±3%±1BPM
  • Display
    65k colors 4.3 inch TFT Display, brightness can be changed.
  • Power
    AC100 - 240 V 50/60 Hz, 60 VA
  • Environmental Conditions
    Working temperature: 15℃ to 40℃(59℉ to 104℉)
    Storage temperature: -20℃ to +65℃(-4℉ to +149℉)
    Relative humidity: < 90%,No condensation.
  • Size (L x W x H)
    27 cm x 26.5 cm x 13.2 cm
  • Weight
    About 4kg

Accessories:

  • Power cord
  • Fuse
  • User 's Manual (GB only)on request for other Language