1
/
of
3
JYTOP
JYTOP S200 Sputum Suction Machine Hospital Surgical Aspirator
JYTOP S200 Sputum Suction Machine Hospital Surgical Aspirator
Regular price
$168.00 USD
Regular price
Sale price
$168.00 USD
Unit price
/
per
Shipping calculated at checkout.
Couldn't load pickup availability
Products Description

Introduction
It is a medical device used to suck respiratory secretions such as pus, blood and phlegm from the patient’s body cavity, adopted a unique vacuum system, easy to operate, safe and reliable to use, low in noise and energy consumption. It can be used in emergency room, operating room and ward.
Function
It is a medical device used to suck respiratory secretions such as pus, blood and phlegm from the patient’s body cavity, adopted a unique vacuum system, easy to operate, safe and reliable to use, low in noise and energy consumption. It can be used in emergency room, operating room and ward.
Function
It is used to suck the mucus such as pus, blood and phlegm from the patient’s body cavity.
Performance
Performance
* High in vacuum and flowrate.
* Power supply: AC 220 V, 50 Hz
* Input power: 110 VA
* vacuum: ≥ 0.08 MPa
* Vacuum regulating range: 0.02 MPa to max. vacuum
* Pumping rate: ≥ 20 L/min
* Collection bottle: 1000 mL
* Noise: ≤ 60 dB (A)
* Mode of operation: non-continuous operation (after working for 30 minutes (maximum allowed time), please turn off the device
and let it cool down for 10 minutes, which can be properly adjusted basing on the time of operation.).
* Degree of safety in presence of flammable gases: non AP / APG equipment (not suitable for use in presence of flammable anaesthetics mixture with air, or oxygen or nitrous oxide)
* The type of protection against electroshock: class Ⅱ
* The degree of protection against electroshock: type B applied part
* Waterproof degree: IPX0
Accessories
* A User Manual
* A main unit
* A suction tubing
* Five disposable suction catheters
* Power supply: AC 220 V, 50 Hz
* Input power: 110 VA
* vacuum: ≥ 0.08 MPa
* Vacuum regulating range: 0.02 MPa to max. vacuum
* Pumping rate: ≥ 20 L/min
* Collection bottle: 1000 mL
* Noise: ≤ 60 dB (A)
* Mode of operation: non-continuous operation (after working for 30 minutes (maximum allowed time), please turn off the device
and let it cool down for 10 minutes, which can be properly adjusted basing on the time of operation.).
* Degree of safety in presence of flammable gases: non AP / APG equipment (not suitable for use in presence of flammable anaesthetics mixture with air, or oxygen or nitrous oxide)
* The type of protection against electroshock: class Ⅱ
* The degree of protection against electroshock: type B applied part
* Waterproof degree: IPX0
Accessories
* A User Manual
* A main unit
* A suction tubing
* Five disposable suction catheters
Share